Sunday, November 13, 2016

Acterna 209OSP T-BERD Outside Plant Tester

Acterna 209OSP T-BERD Outside Plant Tester

Welcome to a Biomedical Battery specialist of the Acterna Battery

Outside plant technicians have to perform a number of tasks: install apparatus cases and splice cables; locate and repair span faults such as bridged taps, load coils, shorts, opens; and verify that cable meets carrier requirements prior to Central Office or Customer Premise equipment installations. With this multitude of tasks, outside plant technicians need a solution that enables them to perform extensive physical layer testing in an all inclusive, easy-to-use test set. The T-BERD Outside Plant Tester (209OSP) with battery like Acterna FTB-100 Battery, Acterna FTB-400 Battery, Acterna MTS-5000 Battery, Acterna MTS-5000E Battery, Acterna MTS-5100 Battery, Anritsu Lite3000(E) Battery, EXFO FTB-100 Battery, EXFO FTB-400 Battery, EXFO FTB-150 Battery, EXFO FTB-200 Battery, EXFO XW-EX002 Battery, EXFO Battery is a complete tool that meets the exclusive testing requirements of the outside plant technicians. It combines copper prequalification features (TDR and DC measurements) with service turn-up and troubleshooting features for T1/FT1/HDSL/ISDN /DDS technologies. The combination of copper analyzer and digital loop tester features makes the T-BERD Outside Plant Tester the most flexible, all-in- one solution for outside plant testing.

Acterna 209OSP Features:

• Input and Output Connectors: WECO 310, 15-pin D, T1 Repeater Port, 8 pin RS-232, RJ48
• Input Impedance: ◦ Bridge: 1000 ohm with ALBO
◦ Term: 100 ohm with ALBO
◦ DSX-MON: 100 ohm with AGC

• Receive Level ◦ Bridge or term: +6 dBdsx to -35 dBdsx (T1), +3 dBdsx to -6 dBdsx (T1C)
◦ DSX-MON: +6 dBdsx to -24 dBdsx (T1), +3 dBdsx to -24 dBdsx (T1C)

• Level Measurement: ◦ +6.0 dBdsx to -40 dBdsx
◦ +6 to -6, 0.1 dB resolution
◦ -6 to -40, 0.5 dB resolution

• Frequency Measurement: 1 Hz resolutions; 5 ppm accuracy
• Transmit Timing Sources: Internal Clock, Recovered Clock
• Line Codes: AMI, B8ZS
• Loopback Codes: CSU, CSU Line (ESF), CSU Payload (ESF), NIU (FAC1, FAC2, FAC3), NIU Network (ESF), Programmable (3 to 8 bits), Intelligent Repeaters, HDSL End-Equipment
• DC Measurements: ◦ Resistance: 10 ohm to 10 Mohm
◦ Volts DC: 0.5 to 400 VDC
◦ Simplex Current: 0 to 200 mA

• TDR Measurements: ◦ Pulse Amplitude: 10.0 V p-p
◦ Measurement Range: 50 to 10,500 ft

• HDSL Measurements: ◦ Loop Loss: 0.0 dB to 40.0 db
◦ Accuracy: ±0.5 dB
◦ Resolution: 0.1 dB
◦ Loop Length: 100 to 20,000 ft
◦ Capacitance: 1500 pF to 323,500 pF
◦ Power: -40.0 to +13.0 dB

No comments: